<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>MPC</ParameterFamily>
<Syntax>
gc edgeposmax
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>M800</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Maximum allowable edge position.
</text></DescriptionText>
<DescriptionText><text>
This parameter is used to check for the case where when searching for the edge of
a small plate, if there is no plate on drum, the edge detection mechanism
finds the edge of the edge detection groove on the drum and incorrectly
thinks it is the edge of a plate.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>480000 [microns]</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>0 to 1200000 [microns]</li>
</UnnumberedList>
</Range>
<LastModified>
29-Mar-2006
</LastModified>
<Notes>
<DescriptionText><text>
This value is determined using the GC process during integration, and
should not have to be changed in the field.
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:24:04 2008 PST
</Updated>
<Links>
</Links>
</Parameter>